Parker Hannifin
home | products | how to buy | support & downloads | literature | search

Click Here to go to new EM&D Knowledge Base (FAQ) site


How do I set my Dynaserv (G3) back to factory default?

Open the 'Terminal' window in the Dynaserv's DrvX3 Support Tool (shipped with the product):

1. Type @90:2003 and then click the 'Send' button.  (this reset the settings)
2. Type @96 and then click the 'Send' button.  (this resets the drive for the default settings to take affect)

Note - Cycling power will also allow the default settings to take affect.

 

glh 9/27/12