Dynaserv G3 Encoder Resolution

Encoder resolutions for the Dynaserv G3 series (post-quadrature):









Motor Model Encoder Resolution#113 (Default)#112 (Default)
DM1A-xxx 4096000 4096000 1024000
DM1B-xxx 2621440 2621440 655360
DM1C-xxx 2621440 2621440 655360
DR1A-xxx 1638400 1638400 819200
DR1B-xxx 1015808 1015808 507904
DR1E-xxx 1228800 1228800 614400
DM5B-xxx 557056 557056 278528
DR5C-xxx 425984 425984 212992
DR5E-xxx 638976 638976 319488
#112 = drive resolution
#113 = scaling (rarely changed from default)

If #112 or #113 is changed, the changed data becomes valid the next time the drive's power is cycled. A software reset will not do--the physical power must be cycled!